• Home
  • Fluke 378 FC Non-Contact Voltage True-RMS AC/DC Clamp Meter with iFlex and Power Quality Indicator

Special Offer: Spend $500 or more on Fluke and get free tool or bundle - Redemption Required Shop Fluke View Details

SKU: Fluke 378 FC
UPC: 095969916615
Weight: 2.26

Fluke 378 FC Non-Contact Voltage True-RMS AC/DC Clamp Meter with iFlex and Power Quality Indicator

List: $929.99 $862.99
+ Free Shipping!
Only 4 left in stock, -3 will be special ordered.

Only 4 left in stock

In Stock

Details

Non-Contact Voltage True-RMS AC/DC 1000v Clamp Meter with iFlex and Power Quality Indicator 5111812 Includes

  • 378 FC Non-Contact Voltage True-rms Clamp Meter
  • iFlex flexible current probe (18 inches; 48 cm)
  • TL224 silicone insulated test leads
  • TP175 adjustable length test probes
  • AC285 grounding clip (black, quantity one)
  • TPAK magnetic hanging kit, with 9 inch (23 cm) hanging strap
  • Premium Carrying case
  • Quick reference guide

Non-Contact Voltage True-RMS AC/DC 1000v Clamp Meter with iFlex and Power Quality Indicator 5111812 Features

  • True-RMS AC/DC clamp meter
  • Includes Power Quality Indicator
  • CAT Rating: CAT III 1000V; CAT IV 600V
  • Capacitance/Resistance: 999.9 µF/ 60 Ω
  • Voltage AC/DC: 1000 V/1000 VGeneral specificationsGeneral Maximum Voltage between any Terminal and Earth Ground1000 VBatteryType2 AA IEC LR6 alkalineLife200 hourDisplayDual readoutAutomatic Power Off20 minutesElectricalAC Current: JawRange999.9 AResolution0.1 AAccuracy2 % ±5 digits (10 Hz to 100 Hz)2.5 % ±5 digits (100 Hz to 500 Hz)Crest Factor (50/60 Hz)3 @ 500 A2.5 @ 600 A1.42 @ 1000 AAdd 2 % for C.F. >2AC Current: Flexible Current ProbeRange2500 AResolution1 A (≤2500 A) 0.1 A (≤999.9 A)Accuracy3 % ±5 digits (5 Hz to 500 Hz)Crest Factor (50/60Hz)3.0 at 1100 A2.5 at 1400 A1.42 at 2500 AAdd 2 % for C.F. >2Position SensitivityDistance from Optimumi2500-10 Flexi2500-18 FlexErrorA0.5 in (12.7 mm)1.4 in (35.6 mm)± 0.5 %B0.8 in (20.3 mm)2.0 in (50.8 mm)± 1.0 %C1.4 in (35.6 mm)2.5 in (63.5 mm)± 2.0 %Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.DC CurrentRange999.9 AResolution0.1 AAccuracy2 % ±5 digits1[1]When using the ZERO function to compensate for offsetsAC Voltage: Field SenseRange1000 VResolution1 V (≤1000V)Accuracy≤4/0 AWG3 % ±5 digits (45 Hz to 66 Hz)≥4/0 AWG5 % ±5 digits (45 Hz to 66 Hz)Position wire as close as possible to jaw opening (see illustration).AC Voltage: Test LeadsRange600.0 V 1000 VResolution0.1 V (≤600.0 V)1 V (≤1000 V)Accuracy1 % ±5 digits (20 Hz to 500 Hz)DC VoltageRange600.0 V1000 VResolution0.1 V (≤600.0 V)1 V (≤1000 V)Accuracy1 % ±5 digitsmV dcRange500.0 mVResolution0.1 mVAccuracy1 % ±5 digitsAmps Frequency: JawRange5.0 Hz to 500.0 HzResolution0.1 HzAccuracy0.5 % ±5 digitsTrigger Level5 Hz to 10 Hz, ≥10 A10 Hz to 100 Hz, ≥ 5 A100 Hz to 500 Hz, ≥ 10 AAmps Frequency: Flexible Current ProbeRange5.0 Hz to 500.0 HzResolution0.1 HzAccuracy0.5 % ±5 digitsTrigger Level5 Hz to 20 Hz, ≥25 A20 Hz to 100 Hz, ≥20 A100 Hz to 500 Hz,≥25 AResistanceRange60.00 kΩ6000 Ω600.0 ΩResolution0.1 Ω (≤600.0 Ω)1 Ω (≤6000 Ω)10 Ω (≤60.00 kΩ)Accuracy1 % ±5 digitsCapacitanceRange1000 μFResolution0.1 μF (≤100.0 μF)1 μF (≤1000 μF)Accuracy1 % ±4 digitsMechanicalSize (L x W x H)274 mm x 86 mm x 47 mmWeight (with Batteries)463 gJaw Opening34 mmFlexible Current Probe Diameter7.5 mmFlexible Current Probe Cable Length (head to electronics connector)1.8 mRogowski Coil Length450 mmEnvironmentalOperating Temperature-10 °C to 50 °CStorage Temperature-40 °C to 60 °COperating Humidity (without condensation)Non condensing (<10 °C)≤90 % RH (10 °C to 30 °C)≤75 % RH (30 °C to 40 °C)≤45 % RH (40 °C to 50 °C)Temperature CoefficientsAdd 0.1 x specified accuracy for each degree C >28 °C or <18 °CIngress ProtectionIEC 60529: IP30 (jaw closed)Operating Altitude2000 mStorage Altitude12 000 mElectromagnetic Compatibility (EMC)InternationalIEC 61326-1: Portable Electromagnetic EnvironmentIEC 61326-2-2, CISPR 11: Group 1, Class BGroup 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.SafetyGeneralIEC 61010-1: Pollution degree 2MeasurementIEC 61010-2-032: CAT III 1000 V / CAT IV 600 VIEC 61010-2-033: CAT III 1000 V / CAT IV 600 VCurrent Clamp for Leakage Current MeasurementsIEC 61557-13: Class 2, ≤30 A/mWireless RadioRadio Frequency CertificationFCC ID: T68-FBLE IC:6627A-FBLEFrequency Range2405 MHz to 2480 MHzOutput Power<100 mWRadio Frequency DataRadio Frequency Data For Class A DevicesSIMPLIFIED EU DECLARATION OF CONFORMITYHereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: https://dam-assets.fluke.com/s3fs-public/FLK_RED_1aeng0900.pdf.