Part Number: DM-5 UPC: 095969808064 Weight: 9.03895275

Description

INCLUDES:

• DM-5 Power Quality Analyzer

• Flexible 3-Sensor Current Transducer

• 1000A Flexible Neutral Current Transducer

• Test Leads with Alligator Clips

• Data Analysis PC Software

• Data Transfer Cable

• 2 GB SD Memory Card

• Power Adapter

• Batteries (AA)

• Large Carrying Case

• Users Manual



FEATURES:

• Quick Setup with On-Screen Guide: A step-by-step setup guide helps ensure you capture the right measurements

• Real-time remote monitoring on compatible PC and Android devices via Bluetooth communication

• Simultaneously measures power, harmonics, waveform, power quality (voltage: 3-channel, current: 4-channel)

• Full Analysis with Included Software: Quickly analyze your recorded data to identify potential issues with report generation and data visualization.

• Test parameters: voltage, current, active/reactive/apparent power, PF and frequency all on one screen

• Power quality events: Swell, Dip, Interruption, transients, Inrush current, and flicker

• Automatic recording with memory for up to 1,000 parameters at user defined intervals

• Comes complete with measurement accessories, PC software, and large carrying case



SPECIFICATIONS:

• Wiring connection: 1P2W, 1P3W, 3P3W, 3P4W

• Measurements and parameters: Voltage, current, frequency, active power, reactive power, apparent power, active energy, reactive energy, apparent energy, power factor (cos ø), neutral current, demand, harmonics, quality (swell/dip/interruption, transients/overvoltage, inrush current, unbalance rate), capacitance calculation for PF correction unit, flicker

• Voltage (rms): Range: 600.0 / 1000 V, Accuracy: ±0.2% + 0.2%f.s.(sine wave, 40 Hz to 70 Hz), Allowable input: 1% to 120% of each range (rms). 200% of each range (peak), Display range: 0.15% to 130 % of each range, Crest factor: 3 or less, Sampling speed of voltage transient: 24 ?s and Input impedance: approx. 1.67 M?

• Current (rms): Accuracy: ±0.2% + 0.2%f.s. + accuracy of flex current sensor (sine wave, 40 Hz to 70 Hz), Allowable input: 1% to 110% of each range (rms). 200% of each range (peak), Display range: 0.15% to 130 % of each range, Crest factor: 3 or less and Input impedance: approx. 100 k?

• Swell / dip / interruption: Range: same as Voltage (rms), Accuracy: ±1.0% of nominal voltage and Threshold value: In percentage of nominal voltage value

• Power and energy: CT-53 flex current sensor (3-ch): max. 6000 kW, CT-500 flex current sensor (1-ch): max. 1000 kW, Active power accuracy: ±0.3% + 0.2%f.s. + accuracy of flex current sensor (PF 1, sine wave, 40 Hz to 70 Hz) Influence of power factor: ±1.0% (PF 0.5, 40 Hz to 70 Hz ), Wh: 0.00000 mWh to 9999.99 TWh, VAh: 0.00000 VAh to 9999.99 TVAh and varh: 0.00000 varh to 9999.99 Tvarh

• Power factor:Display range: -1.000 to 0.000 to 1.000 and Accuracy: ±1dgt against each calculated value (for sum: ±3dgt)

• Harmonics:Harmonics order (n): 1 to 50th Inter-harmonics order (n): 1 to 50thVolts: 0.0% to 100.0%, accuracy (?3% at 100 V nominal voltage): ±10%,accuracy (<3% at 100 V nominal voltage): ±0.3% of nominal voltage accuracy (1000 V range): ±0.2% + 0.2%f.s, Amps: 0.0% to 100.0%, accuracy (?10% to max. input range): ±10% + flex current sensor accuracy (<10% to max. input range): ±1.0% + flex current sensorWatts: 0.0% to 100.0%, accuracy: ±0.3% + 0.2%f.s. + accuracy of flex current sensor (PF 1, sine wave, 50/60 Hz) THD: 0.0% to 100.0%, Phase angle: 0.0° to ± 180°

• Flicker: Displayed items: Pst(1min), Pst, Plt, Max Pst, Max Plt, V, time left, Measurement method: Complied with IEC 61000-4-30 and IEC 61000-4-15 Ed.2 and Accuracy: Pst (max.20): ±10% according to IEC 61000-4-15

• Unbalance: Volts: 0.00% to 100.00%, accuracy: ±0.3% at 50/60 Hz, sine wave (0.00% to 5.00% according to IEC 61000-4-030) and Current: 0.00% to 100.00%

• Transient: Approx. 40.96 ksps (every 2.4 ?s), Range: 50 V to 2200 Vdc and Accuracy: ±0.5% at 1000 Vdc

• Inrush current: Range: same as Current (rms), Accuracy: ±0.4% + 0.4%f.s. + accuracy of flex current sensor and Threshold value: In percentage of the measurement range

• Capacitance: Range: 0.000 nF to 9999 F, 0.000 kvar to 999 kvar





The new Amprobe DM-5 Power Quality Analyzer allows you to easily and quickly discover the source and magnitude of power quality issues. Poor power quality is costly – not only can it drive up energy bills with excessive power usage, but equipment failure or damage caused by poor power quality is expensive and time-consuming to diagnose and repair. Productivity and process also suffer with faulty equipment or unscheduled outages. At half the size of previous models, the compact DM-5 brings speed and efficiency to power quality jobs ranging from routine maintenance to in-plant troubleshooting of individual machinery and power distribution panels. Built for use in even one of the largest facilities, the DM-5 is safety tested to meet the world’s most prestigious safety standards and is rated to CAT IV 300 V, CAT III 600 V, CAT II 1000 V. REAL-TIME CHECKS WITH LARGE, FULL-COLOR SCREEN: During and after measurements, the on-board screen displays data graphs and values in full color for easy comparison. Additionally, the Print Screen quick-button makes it simple to save momentary readings for later comparison. WIRELESS CONTROL FOR REMOTE CHECKS AND ADJUSTMENTS: Adjust settings and transfer data remotely by connecting the DM-5 to compatible Bluetooth enabled Windows and Android devices. This provides added convenience and safety, allowing for easy testing modifications even when the main unit is in difficult to access locations. FULL ANALYSIS WITH INCLUDED SOFTWARE: Quickly analyze your recorded data to identify potential issues with report generation and data visualization.